Split Core CT

Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT
Split Core CT

Current Transformer (5-1000A/5A), AKH-0.66K series

AKH-0.66K split-core current transformers are built primarily for power grid construction or retrofit projects. The current transformers can be easily installed onto an existing power system without removing the primary busbar or shutdown the system, guaranteeing customer’s daily use of electricity. Customer will benefit from reduced labor intensity, lowered operating cost and improved work efficiency. These current transformers can perfectly work with relay protection, measuring and metering devices.


Split Core Current Transformer, AKH0.66K-φ10

  • Measurement: alternating current (AC)
  • Accuracy: Class 0.5
  • Primary current input: 5~60A AC
  • Rated voltage: 660V AC
  • Rated frequency: 50~60Hz
  • Installation: clamp-on (installed on cable)
  • Loop count: 1 loop
  • Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

Split Core Current Transformer, AKH0.66K-φ16

  • Measurement: alternating current (AC)
  • Accuracy: Class 0.5
  • Primary current input: 20~100A AC
  • Rated voltage: 660V AC
  • Rated frequency: 50~60Hz
  • Installation: clamp-on (installed on cable)
  • Loop count: 1 loop
  • Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

Split Core Current Transformer, AKH0.66K-φ24

  • Measurement: alternating current (AC)
  • Accuracy: Class 0.5
  • Primary current input: 60~400A AC
  • Rated voltage: 660V AC
  • Rated frequency: 50~60Hz
  • Installation: clamp-on (installed on cable)
  • Loop count: 1 loop
  • Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

Split Core Current Transformer, AKH0.66K-φ36

  • Measurement: alternating current (AC)
  • Accuracy: Class 0.5
  • Primary current input: 100~600A AC
  • Rated voltage: 660V AC
  • Rated frequency: 50~60Hz
  • Installation: clamp-on (installed on cable)
  • Loop count: 1 loop
  • Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

Split Core Current Transformer, AKH0.66K-φ50

  • Measurement: alternating current (AC)
  • Accuracy: Class 0.5
  • Primary current input: 600~800A AC
  • Rated voltage: 660V AC
  • Rated frequency: 50~60Hz
  • Installation: clamp-on (installed on cable)
  • Loop count: 1 loop
  • Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

Current Transformer (20-5000A/5A), AKH-0.66K series

Acrel offers Hall-effect Current Sensors that support a wide range of rated outputs, and feature compact design with high accuracy, by which the current can be measured without requiring to break the conductor, thereby providing fast installation.

Technical Data
Type Ratio (A) Burden(VA)
Class 0.2 Class 0.5
K-60*40 400/5 1.5
500/5 2.5
600/5 2.5
800/5 2.5
1000/5 5
1500/5 10
K-80*40 800/5 2.5
1000/5 5
1500/5 10
2000/5 10
3000/5 10
K-100*40 1500/5 10
2000/5 10
3000/5 10
4000/5 15
K-120*60 1500/5 10
2000/5 10
3000/5 10
3000/5 10
4000/5 15
5000/5 15
K-140*60 2000/5 10
3000/5 10
4000/5 15
5000/5 15
K-160*80 3000/5 10
4000/5 15
5000/5 15
6000/5 15
Related products
Send Message