CMS 30kVA UPS system uses modules with power of 30kVA and is scalable to a maximum of 150kVA power capacity. Sicon provides the following 4 standard 3 phase modular UPS systems.

CMS 60KVA UPS System
  • Maximum power: 60kVA
  • Power module model: CM30
  • Module power: 30kVA
  • Direct voltage: ±240V
  • Dimension: 600*800*1200mm (W*D*H), standard 19 inch cabinet
  • Weight: 150kg
CMS 90KVA UPS System
  • Maximum power: 90kVA
  • Power module model: CM30
  • Module power: 30kVA
  • Direct voltage: ±240V
  • Dimension: 600*800*1200mm (W*D*H), standard 19 inch cabinet
  • Weight: 200kg
CMS 120KVA UPS System
  • Maximum power: 120kVA
  • Power module model: CM30
  • Module power: 30kVA
  • Direct voltage: ±240V
  • Dimension: 600*800*1600mm (W*D*H), standard 19 inch cabinet
  • Weight: 200kg
CMS 150KVA UPS System
  • Maximum power: 150kVA
  • Power module model: CM30
  • Module power: 30kVA
  • Direct voltage: ±240V
  • Dimension: 600*800*1600 mm (W*D*H), standard 19 inch cabinet
  • Weight: 260kg
UPS System Technical Parameters
Module
Module model CM30
Module power 30 kVA
Power connection 3/3 phase
Module dimension (W*D*H)mm 482*465*133
Weight(kg) Approximate 20 kg
Module charging Each module provides 7.5kVA charging power
Input power factor ≥ 0.99
Maximum heat dissipation power 1900W
THDI (%) ≤ 3%
Mains Input
Input mode 3-phase +N +E, 1-phase +N +E
Input voltage 380V/220V±20%, 400V/230V±20%, 415V/240V±20%
Input frequency 50Hz±10%, 60Hz±10%
Power woke-in (Sec.) 60sec
THDI (%) <3%
Input PF ≥0.99
Bypass Input
Input voltage 380V/220V±20%, 400V/230V±20%, 415V/240V±20%
Input frequency 50 Hz, 60 Hz
Range of Frequency Synchro 50 Hz±4%, 60 Hz±4%
DC Input
Rated Input voltage ±384VDC
Input voltage tolerance ±345V~±440V DC
Battery charging
Charging current limited yes
Charging ability 10 hours (2 hours back up)
Stability of charging voltage ±1%
AC output
UPS power factor 1
Output voltage 380V/220V AC, 400V/230V AC, 415V/240V AC
Output frequency ±4%;±0.2% (battery supply)
Output voltage stability ±1%
Output voltage recovering time <20ms (load 0~100% change)
Overload ability Operate 10mins with 125% load
Transfer from mains to battery supply 0ms
Transfer from bypass to inverter supply < 1ms
Peak factor 3:01
Waveform distortion ≤1% ( linear load ), ≤3%( non-linear load )
Overall efficiency ≥95% (AC~AC), ≥98% (DC~AC)
Load share precision ≤5%
Operation environment
Ambient temperature -25℃~60℃
Operating temperature -5℃~40℃
Maximum operation altitude ≤1500m
Relative humidity ≤95% non-cadency
Protection degree IP30
Cooling Air cooling
Applicable safety standards EN62040-1-1:2003 IEC60950-1:2001
Electromagnetic compatibility EN62040-2:2006
Acoustic noise ≤55DB
Others
Cabinet Standard 19 inch cabinet
Monitor management system UPSupervisor
Interface RS232, RS485 and 8 try contact, TCP/IP adapter, SNMP(optional)
Display Touch LCD/LED Screen