YDB series Pressure Steam Sterilizer

YDB series Pressure Steam Sterilizer
Description

The YDB series pressure steam sterilizer adopts automatic program operation and LED digital display screen to display a dialogue box for monitoring the whole sterilizing process. The sterilization process is automatically controlled with no need for supervision and easy operation. The sterilizing temperature is adjustable within 105-134 ℃. And the sterilizing program can be set randomly to sterilize different kinds of objects.

Application

The YDB series pressure steam sterilizer adopts saturated steam pressure to sterilize objects. The pressure saturated steam can release a large amount of latent heat during condensation. Due to this physical property, the to-be-sterilized object is under high temperature and humid state. After certain time, the bacteria and spore tissue in the object will be all destroyed, realizing sterilization. With an automatic program operation, the YDB series pressure steam sterilizer is mainly used in hospitals, the chemical industry, food, scientific research and other workplaces for sterilizing surgical instruments, dressings, medicine, culture mediums and so on.

Features of YDB series pressure steam sterilizer
  • When it enters the drying program, the automatic countdown begins. And the sterilizer will automatically cut off the heating power after the sterilization. Then it alarms to indicate that the program operation is finished.
  • With over-temperature and over-pressure automatic protection devices, this sterilizer will automatically cut off the heating power when the temperature is too high. And it will open the safety valve for automatic pressure releasing protection when the pressure is too high.
Parameters of YDB150
Model WS-150YDB
Equipment capacity 150L (Φ440 x1000mm)
Maximum working pressure 0.22MPa
Maximum operating temperature 134℃
Temperature uniformity of sterilization chamber ≤±2℃
Temperature range 105℃~134℃
Timing range 0~99min.
Drying time range 0~99min.
Voltage 9KW/AC380V 50Hz
Performance Automatic water feeding, cold air discharge, sterilization, timing, steam discharge, drying, alarm.
Safety equipment Over pressure protection, overheat protection, automatic constant pressure control, low water level protection, over current protection, the door cannot be opened when the internal pressure exceeds 0.027Mpa, and it has a safety interlocking device.
Size 140×65×160 (cm)
Shipping size 156×82×182 (cm)
Net weight/Gross weight Net: 340kg / Gross: 430KG
Parameters of YDB200
Model WS-200YDB
Equipment capacity 200L (Φ515 x 1000mm)
Maximum working pressure 0.22MPa
Maximum operating temperature 134℃
Temperature uniformity of sterilization chamber ≤±2℃
Temperature range 105℃~134℃
Timing range 1~99min.
Drying time range 1~99min.
Voltage 9KW/AC380V 50Hz
Performance Automatic water feeding, cold air discharge, sterilization, timing, steam discharge, drying, alarm.
Safety equipment Over pressure protection, overheat protection, automatic constant pressure control, low water level protection, over current protection, the door cannot be opened when the internal pressure exceeds 0.027Mpa, and it has a safety interlocking device.
Size 140×75×170 (cm)
Shipping size 156×91×188 (cm)
Net weight/Gross weight Net: 350kg / Gross: 436Kg
Parameters of YDB280
Model WS-280YDB
Equipment capacity 280L (Φ600 x 1000mm)
Maximum working pressure 0.22MPa
Maximum operating temperature 134℃
Temperature uniformity of sterilization chamber ≤±2℃
Temperature range 40℃~134℃
Timing range 0~99min.
Drying time range 0~99min.
Voltage 12KW/AC380V 50Hz
Performance Automatic water feeding, cold air discharge, sterilization, timing, steam discharge, drying, alarm
Safety equipment Over pressure protection, overheat protection, automatic constant pressure control, low water level protection, over current protection, the door cannot be opened when the internal pressure exceeds 0.027Mpa, and it has a safety interlocking device.
Size 91×152×190 (cm)
Shipping size 108×168×210 (cm)
Net weight/Gross weight Net: 462kg / Gross: 570Kg
Safety interlocking device
  • The steam cannot enter the inner body if the door is not closed properly and it will alarm the operator.
  • When the pressure in the sterilizing chamber exceeds 0.027MPa, the door is securely locked.
  • Over-pressure protection: when the pressure exceeds the working pressure, the safety valve will release pressure automatically for protection.
  • Low water level protection device: if there is too much water, it cannot be heated. And the power will be automatically cut off and alarms when the water level is low.
  • Overcurrent protection: the power circuit breaker will cut off the power supply automatically if the current is overloaded.
  • Print function: it can record and print the whole sterilizing process.
Related products