Medical Oxygen Concentrator
Development of urbanization with more energy consumption has brought about some negative impacts on human health. Pollution caused by automobile exhaust and industrial gases lead to higher incidence for respiratory diseases which usually occur on the trachea, bronchi, lungs or the chest. Patients suffering from respiratory diseases may feel difficult to breathe and are incapable to ingest enough oxygen. Some may even die from organ failure.
A high quality medical oxygen concentrator will be greatly helpful for the adjuvant therapy for patients with respiratory diseases. Our company can produce various types of medical oxygen concentrating machines suitable for different patients.
Technical Parameters of Oxygen Concentrators for Medical UseModel | | | | |
Flow Rate | 0.5-5L/min | 0.5-8L/min | 0.5-10L/min | 0.5-10L/min |
Oxygen Purity | 93% (±3%) | |||
Outlet Pressure | 6-10 PSI (0.04-0.07 Mpa) | 20 PSI (0.14Mpa) | ||
Sound Level | ≤50dB | |||
Net weight | 25Kgs | 26Kgs | 27Kgs | 29Kgs |
Power Consumption | ≤ 550W | ≤ 880W | ||
Input Frequency | 50Hz; 60 Hz | |||
Input Voltage | AC230V±10%; AC110V±10% | |||
Alarm | 1. Power failure alarm; 2. High and low pressure alarm; 3. Low oxygen purity alarm: When oxygen purity is >82%, blue light illuminates; When oxygen purity is < 82%, red light illuminates for indicating low purity ; |
- Features
- Our medical oxygen concentrator can output oxygen with concentration higher than 90% and it makes noise lower than 50dB while working.
- Designed with reasonable structure, the machine components are wear-resistant and durable.
- Our oxygen gas generator will help relieve your disease symptoms and balance the vital energy and blood in your body.
- We have medical oxygen concentrators in various models such as the , , and the . All our products are up to the standard of ISO9001. You can select a proper one according to your practical need.
- Optional
- Nebulizer (Atomizer)
- Low concentration alarm: when oxygen concentration is 82% or above, the blue light will be on; when the oxygen concentration is blow 82%, the red light will be on.
- Maintenance alarm: alarm for maintenance after 3000 hours' operation.
- High temperature alarm: alarm for high temperature when the internal system temperature is above 50 ℃.
- Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
- Small LCD display: showing accumulated time, present working time and preset time.
- Dual flow configuration