400-2000kW Induction Central Heating Boiler

400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler
400-2000kW Induction Central Heating Boiler

Heating area: 3840-14400m²

Features
  • Electrical leakage protection;
  • High pressure protection;
  • Alarm function;
  • Short circuit protection;
Send Inquiry
Parameter
Model Unit
BYD-C480SLC1
BYD-C640SLC1
BYD-C800SLC1
BYD-C1000SLC1
BYD-C1200SLC1
Rated power KW 480 640 800 1000 1200
Rated current A 720 960 1200 1500 1800
Voltage/Frequency V/Hz 380/50-60 380/50-60 380/50-60 380/50-60 380/50-60
Cross section area of power cable ≥300 ≥400 ≥500 ≥500 ≥600
Heating efficiency % ≥98 ≥98 ≥98 ≥98 ≥98
Max. pressure of heating Mpa ≤0.2 ≤0.2 ≤0.2 ≤0.2 ≤0.2
Minimum flow rate of water pump L/min 576 768 960 1200 1440
Expansion tank volume L 480 640 800 1000 1200
Max. heating temperature 90 90 90 90 90
Temperature of low temperature protection 5 5 5 5 5
65ºC hot water output L/min 156 208 260 325 390
Dimensions mm 2610*1100*1950 3480*1100*1950 4350*1100*1950 5220*1100*1950 6960*1100*1950
Inlet/outlet connection DN 125 125 150 150 150
Heating area 3840-5760 5120-7680 6400-9600 8000-12000 9600-14400
Heating space 16560-22950 22080-30600 27600-38250 34500-47800 41400-57300
Electric meter A 3-phase power meter 1.5-1.6A, metering transformer needs to be installed rationally by professional personnel
Protection grade IP 33 33 33 33 33
Heat dissipation of enclosure % ≤2 ≤2 ≤2 ≤2 ≤2
Max. volume of heating L 8800 11700 14700 18300 22000
Features

Energy Saving
When the indoor temperature exceeds the pre-set value, the central heating boiler will be automatically turned off, thus efficiently saving more than 30% energy. And it can save energy by 20% in comparison with traditional boilers that use resistance heating method.

Constant Temperature and Comfortable Space
Water temperature can be controlled within a range of 5~90ºC, and the precision of temperature control can reach ±1ºC, providing a comfortable atmosphere for your space. Unlike air conditioning equipment, induction heating does not create an ideal environment for bacteria to grow.

No Noise
In contrast to central heating boilers using air cooling method, water cooled heating boilers are more quiet and unobtrusive.

Safe Operation
Utilizing induction heating achieves separation of electricity and water, providing a safer operation. Besides, multiple protection functions such as antifreeze protection, electricity leakage protection, short circuit protection, phase loss protection, overheating protection, overcurrent protection, overvoltage protection, undervoltage protection, self-inspection protection are equipped. Safe usage is guaranteed for 10 years.

Intelligent Control
Our induction central heating boilers can be WIFI remotely controlled by smart phones.

Easy to Maintain
Induction heating do not constitute the condition of fouling, eliminating the need for fouling removing treatment.

Installation
  • Direct Installed Heating Mode
  • Installation Method of Fan Coil Unit
  • Idirect Heat Sink Installation
  • Hot Water Storage Tank Installation
FAQ

Please Contact Our Customer Service before Make a Purchase

  • About Choosing Appropriate Power

    Choosing a suitable boiler based on your actual heating area
    For low-energy buildings, 60~80W/m² boilers are suitable;
    For general buildings, 80~100W/m² boilers are suitable;
    For villas and bungalows, 100~150W/m² boilers are suitable;
    For those buildings where sealing performance is not well and room height is greater than 2.7m or people frequently enter, the building heat load is correspondingly increased and the power of central heating boiler should be higher.

  • About Installation Conditions

    What are installation conditions
    Take a 15kW induction central heating boiler as an example:
    The cross section are of main power cable should not be less than 6mm3, main switch 32~45A, voltage 380V/50, minimum water flow of pump is 25L/min, the water pump needs to be selected according to building height.

  • About Accessories

    What accessories are required
    Since every installation site of customer is different, so that various accessories are required. We only provide central heating boilers, other accessories such as pump valve, piping and union connectors need to be purchased by customers.

  • About Connections For Heating

    What are applicable connections for heating
    BIYDA’s induction central heating boilers can be flexibly connected to floor heating system, radiator, hot water storage tank, fan coil unit (FCU), etc.

  • About Installation Service

    Our products can be installed by our authorized local dealers. We also accept advance reservation, and we designate engineers to offer installation service and technical guidance on site.

  • About Logistics

    Shipping time and logistic distribution
    We promise to ship our ready-to-ship products within 24 hours, and ship our made-to-order products within 7-10 days. And the logistics service is based on customers’ requirements.

  • About Service Life

    How long is this product’s service life
    BIYDA’s induction central heating boiler adopts high-frequency induction coil and industrial grade inverter, all key parts are made of imported high grade materials, its service life can reach 15 years or more.

Case Studies

Project: Hot water supply and space heating for Hohhot High Security Prison
Heating demand: The heating method of 3 railway stations, namely Golmud Mahai Station, Dachaidan Station and Yuqa Station, is replaced by electric energy heating instead of the previous coal-fired heating
Products used: 9 sets of 500-800kW inverter electromagnetic heating units
Introduction: These three railroad stations belong to the Qinghai-Tibet Railway at an altitude of over 3300. The total heating equipment provided by us has an installed power of over 6000KW, which enables electromagnetic heating to replace coal-fired heating, not only for environmental protection, but also to save heating costs. Our solution eventually became a demonstration project for the Qinghai-Tibet Railway system heating.

Project: Heating solution for Aishang Chancery residential district in 2020
Project Address: Gongzhuling, Jilin, China
Temperature: -20℃
Project Overview: Centralized heating for a new community with a construction area of about 100,000 square meters, with an actual heating area of about 80,000 square meters, using a valley electric storage heating solution.
Products used: 8 sets of 800KW BIYDA high quality induction heating furnace 1000 cubic meters of heat storage water tank
Heating temperature: 25℃ indoor
Operation cost: 22 RMB/sqm in heating season (lower than central heating cost)

Project: Water heating solution for Tonghua Normal College Bathhouse
Products used: 480kW inverter induction water heater
Client feedback: BIYDA inverter induction circulating hot water furnace can supply hot water steadily for a long time and guarantee the school's bathroom to achieve 12-hour hot water supply. It is convenient for teachers and students to take a bath.

Related products
Send Message