Rebar Locator

Rebar Locator
Rebar Locator
Rebar Locator
R630A Rebar Locator

R630A rebar locator is used to test the location of rebar in concrete, the thickness of the protective layer, and the diameter, orientation, and distribution of rebar by using an electromagnetic induction method. The rebar locator also can be used to test the distribution of magnetic and conductor such as cables and metal pipes in non-magnetic medium and non-conducting medium.

Technical Parameters
Measuring range Ф6mm~Ф50mm Max. allowed error ±1 rebar standard
Protective layer thickness range (mm) First range Second range Data transmission GPRS wireless transmission, thumb drive storage available
3~98 3~196 Power Built-in chargeable lithium battery
Max. allowed error for protective layer thickness ±1mm 3~56 3~79 Battery time >38hrs
±2mm 57~69 80~119 Size 212x134x50mm
±4mm 70~98 120~196 Weight 0.9kg
R660 Rebar Locator

R660 rebar locator is designed to determine the location, distribution, direction, and diameter of rebar and thickness of concrete, covering almost all concrete structure projects such as bridges, tunnels, walls, etc.

Technical Parameters
Thickness measuring range Small range: 2~100mm
Large range: 2~200mm
Power supply Built-in lithium battery
Continuous operating time ≥10hours
Whole dimension 241×94×119mm
Display screen 320x240 half-transparent and half-reflecting color display screen
Storage capacity Up to 3,584 objects
Operating mode Film button
Communication interface USB transmission interface and Bluetooth transmission interface
R800 Rebar Locator

R800 rebar locator is a multi-functional integrated rebar detector which can be used for testing the thickness of protective layer, measuring the diameter, location, and distribution of rebar as well as for detecting the corrosion content of rebar.

Technical Parameters
Measuring range of rebar diameter Ø6mm~50mm Corrosion detection method Single electrode Double electrode
Rebar cover meter
range (mm)
First range Second range Measuring range ±1000mV 0~1000 mV
3~98 3~196 Accuracy ±1mV ±1mV
Max. allowed error
for cover
meter
±1mm 6~56 3~77 Tested points interval X 0~100 adjustable 20 fixed
±2mm 58~69 80~118 Tested points interval Y 0~100 adjustable 0~100 adjustable
±4mm 70~98 120~196 Power Built-in chargeable lithium battery
Max. allowed error for diameter measurement ±1 rebar standard level Battery time >38hours
Data transmission USB Dimension 212x134x50mm
USB port Thumb drive storage available Weight 0.9kg
Related products