FEATURES :
The input and output power capacity for each circuit is 500W.
The detection time is less than or equal to 300ms.
A certain zone operates normally, the status indicator becomes green and is on constantly;
A certain zone is not connected with any load during initialization, the indicator is not on during the device operating;
Immediately after starting, the indicators of all zones become green and flash;
The load connected to a certain zone is disconnected during the device operating, the indicator becomes yellow and is on constantly;
The load connected to a certain zone is too light, the indicator becomes yellow and flashes;
The load connected to a certain zone is too heavy, the indicator becomes red and flashes;
A certain zone has short circuit, the indicator becomes red and is on constantly. The buzzer will also give warnings, and this zone will stop output automatically.
Corresponding table for address :
Address | Number | Address | Number | Address | Number | Address | Number |
Address 1 | 0000 | Address 5 | 0100 | Address 9 | 1000 | Address 13 | 1100 |
Address 2 | 0001 | Address 6 | 0101 | Address 10 | 1001 | Address 14 | 1101 |
Address 3 | 0010 | Address 7 | 0110 | Address 11 | 1010 | Address 15 | 1110 |
Address 4 | 0011 | Address 8 | 0111 | Address 12 | 1011 | Address 16 | 1111 |
The detector terminal box can be divided into two categories according to their power, i.e. PC1026r-10 (power: 10W) and PC1026R-50 (power: 50W). Terminal detector box with different power should be selected according to the specific project configuration.
1) If the total power of the detected line is lower than 10w, the terminal detector box PC1026R-10 should be selected;
2) If the total power of the detected line is between 10W~50W, the terminal detector box PC1026R-50 should be selected;
3) If the total power of the detected line is more than 50W, two or above terminal detector boxes should be connected in a parallel way, so as to complete the monitoring over zone line. The connection type in the system zone is show as follows: All the following connection legends are just examples for connection types and projects in some zones. Specific connection should be made according to the actual site requirement.
Prompt: The Line detector can be connected to the hot or cooling end of transmission line in a serial way.
(I) Elevation of PC1026R-10/50:
(II)Connection diagram for PC1026R-10 in the line (take line connection in zone 2 as an example): (one branch connection for one line)
If there is more than one branch in one zone, the following connection type is available: (multiple-branch connection in one line)
(III)Connection diagram for PC1026R-50 in the line (take line connection in zone 1 as an example): (one branch connection for one line)
If there is more than one branch in one zone, the following connection type is available: (multiple-branch connection in one line)
(IV)If the total power of the monitored line is more than 50W, two or above line monitoring boxes should be connected in a parallel way. For example: If the total power of the speaker in the line is 60W, one PC1026R-50 and one PC1026R-10 can be connected with each other in a parallel way. For example: If the total power of the speaker in the line is more than 100W, two PC1026R-50s can be connected with each other in a parallel way. The number of parallel line monitoring box should be determined depending on the actual demand. Connection diagram is shown as follows: