JX Thermocouple Extension Wire(Kapton Insulated Wire)

JX Thermocouple Extension Wire<small>(Kapton Insulated Wire) </small>
JX Thermocouple Extension Wire<small>(Kapton Insulated Wire) </small>
JX Thermocouple Extension Wire<small>(Kapton Insulated Wire) </small>

As a professional thermocouple supplier, MICC also provides various kinds of thermocouple wire besides our Kapton insulated JX thermocouple extension wire. Welcome to contact us for any questions about our products.

Material
1. Conductors
Positive: iron
Negative: constantan
2. Insulation: braid KPT (Kapton)
3. Overall sheath: braid KP

1. Subject
The specification is about our Kapton insulated JX thermocouple extension wire, which comes with stranded wire and standard tolerance.

2. Technical Feature
A. Conductor
Standard thermocouple extension wire
Conductor size (AWG) Quantity of strands and gauge
24mm 7/32 AWG (Ø0.2mm)

B. Insulation
Braid KPT (260℃)
Nominal insulation thickness: 0.15mm
Color code:
Positive: white
Negative: red

C. Assembly
The two conductors (positive and negative) of the Kapton insulated JX thermocouple extension wire are in parallel.

D. Overall sheath
Silicone rubber (260℃)
Nominal sheath thickness: 0.10mm
Color code (ASTM E230/ANSI): brown

3. Dimensions and Tolerance
Dimensions/tolerance (mm): (1.3±0.15)×(2.1±0.15)

4. Calibration Tolerance of the Kapton Insulated JX Thermocouple Extension Wire
Temperature range Standard tolerance* Special tolerance*
0℃ - 200℃ ±2.2℃ or 0.75% ±1.1℃ or 0.4%

* whichever is greater

Thermocouple type available: KX, JX, TX, EX, NX, RX,SX and other compensating cable like KCA, KCB and so on.

Related products
Send Message