Meters and Measurement Devices for Exact Consumption Data Acquisition
This electromagnetic meter is designed separately for the flow sensor, temperature sensor and integral calculator. This split heat meter is suitable for remote installation and monitoring, as well as providing volume flow measurement for conductive fluids in a closed pipe.
Basic Controls provides electromagnetic meters in different pressure grades for clients to satisfy their different application needs.
Parameters- Line material: cast iron/carbon steel
- Connection: flange connection
- Nominal diameter range: DN20-DN1000
- Pressure grade: PN16 (PN25 can be customized)
- Waterproof grade: IP65 (IP68 can be customized)
Flow rate | Nominal diameter | Flow range (m3/h) | Bolt hole | Bolt count on each side-bolt hole diameter | Flange outer diameter | Length | ||
Overload flow rate | Normal flow rate | Minimal flow rate | D1(mm) | n-M | D(mm) | L (mm) | ||
N2.5 | DN20 | 5 | 2.5 | 0.1 | 75 | 4×M14 | 105 | 150 |
N3.5 | DN25 | 7 | 3.5 | 0.14 | 85 | 4×M14 | 115 | 150 |
N6 | DN32 | 12 | 6 | 0.24 | 100 | 4×M18 | 140 | 150 |
N10 | DN40 | 20 | 10 | 0.25 | 110 | 4×M18 | 150 | 200 |
N15 | DN50 | 30 | 15 | 0.6 | 125 | 4×M18 | 165 | 200 |
N25 | DN65 | 50 | 25 | 1 | 145 | 8×M18 | 185 | 200 |
N40 | DN80 | 80 | 40 | 1.6 | 160 | 8×M18 | 200 | 200 |
N60 | DN100 | 120 | 60 | 2.4 | 180 | 8×M18 | 220 | 250 |
N100 | DN125 | 200 | 100 | 4 | 210 | 8×M16 | 250 | 250 |
N150 | DN150 | 300 | 150 | 6 | 240 | 8×M22 | 285 | 300 |
N250 | DN200 | 500 | 250 | 10 | 295 | 12×M22 | 340 | 350 |
N400 | DN250 | 800 | 400 | 16 | 355 | 12×M22 | 395 | 400 |
N600 | DN300 | 1200 | 600 | 24 | 410 | 12×M22 | 445 | 450 |
N800 | DN350 | 1600 | 800 | 32 | 470 | 16×M22 | 505 | 500 |
N1000 | DN400 | 2000 | 1000 | 40 | 525 | 16×M26 | 565 | 600 |
N1250 | DN450 | 2500 | 1250 | 50 | 585 | 20×M26 | 615 | 600 |
N1500 | DN500 | 3000 | 1500 | 60 | 650 | 20×M26 | 670 | 600 |
N2000 | DN600 | 4000 | 2000 | 80 | 770 | 24×M30 | 780 | 600 |
N2500 | DN700 | 5000 | 2500 | 100 | 840 | 24×M30 | 890 | 700 |
N3000 | DN800 | 6000 | 3000 | 120 | 950 | 24×M33 | 1015 | 800 |
N4000 | DN900 | 8000 | 4000 | 160 | 1050 | 28×M33 | 1115 | 900 |
N5000 | DN1000 | 10000 | 5000 | 200 | 1170 | 28×M36 | 1230 | 1000 |
Transmitter technical parameters
Range ratio | 1.042361111 |
Repeatability error | ±0.1% of measured value |
Accuracy class | 2 class |
Electrode material | 316L |
Protection grade | IP65 |
Power supply | AC220V/50Hz |
Output signal | Analog output: 4~20mA |
Measuring media | Water |
Ambient temperature | 5℃~+55℃ |
Relative humidity | 5%~95% |
Rated working pressure | ≤1.6Mpa (or 2.5Mpa) |
Liner material and media temperature | Polytetrafluoroethylene liner: -30~+150 ℃ |
Neoprene liner: -20~+80 ℃ | |
Connection type | Flange connection |
Total power consumption | ≤20W |
Related products
Send Message
Most Recent
More
Other Products
Videos