TB-12Toca Patient Monitor

TB-12Toca Patient Monitor
TB-12Toca

Ⅰ. Features
1. TB-12Toca patient monitor comes with a 12.1" high brightness TFT LCD display.
2. It applies touch screen design and big figure display.
3. This medical monitor synchronically displays 7-lead ECG waveforms on its screen.
4. It stores 96-hour tabular and graphic trends. Additionally, it has the function such as date storage.
5. Another function of the multi-parameter patient monitoring device is NIBP dual over-pressure protection.
6. The medical equipment is featured by isolated floating as well as good resistance to defibrillation and high-frequency interference.

Ⅱ.Standard Settings
3/5 lead ECG, Respiration(RESP), SpO2, NIMP, Temperature, Pulse Rate(HR), Network

Ⅲ.Optional Configurations
2-IBP, Recorder, 12 lead ECG, ETCO2, Mobile trolley, Wall mount, Central station system

Ⅳ. Parameters of TB-12Toca Patient Monitor
1. General
Safety standard: IEC60601, CE approval
Anti-electroshock type: Class I equipment and internal powered equipment
EMC type: ClassA
Anti-electroshock degree: ECG (RESP), SpO2, NIBP, IBP, TEMP, CO2, CF
Harmful liquid proof degree: Ordinary equipment
Working system: Continuous running equipment

2. Size and Weight
a. Size: 310*263*140mm
b. Weight: 3.8kgs

3. Display
a. Type: 12.1”TFT, 800*600, touch screen interface
b. Function: Synchronically display 7 waveforms on one screen.
c. Other functions: Power/standby indicator and battery indicator

4. Battery
a. Type: Rechargeable lithium battery
b.Regular Working Time: Above 2 hours
c. It can last 5 minutes after first alarm of low battery.

5. Recall
a. Trend recall: 72hours, I-minute resolution
b. Alarm event recall: All parameters
c. NIBP measurement recall: 1400 NIBP measurement data

6. ECG
a. Lead mode: 5 leads (R, L, F, N, C or RA, LA, V, RL, LL)
3 leads (R, L, F or RA, LA, LL)
b. Lead Selection: I; II; III; avR; avL;avF; V; (5-lead)
I, II, III (3-lead)
c. Gain: ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV
d. HR Measurement and Alarm Range
Range: 15-300bpm
Display Error: ±1% or 1bpm, which is higher
Alarm Error: ±2bpm
e. CMMR:
MON: ≥100dB
OPE:: ≥100DbB
DIA: ≥60DbB
f. Frequency Response:
MON: 0.5Hz-40Hz( 0.4dB, -3dB)
OPE:: 1Hz-20Hz( 0.4dB, -3dB)
DIA: 0.05Hz-75Hz( 0.4dB, -3dB), 76Hz-150Hz( 0.4dB, -4.5dB)
g. Baseline Recovery Time: <5sec following defibrillation
h. ECG Calibration: 1mV (peak value)
i. Scan Speed: 12.5mm/25mm/50mm/sec
j. Lead Drop: Auto detection
k. ST Segment:
Measurement and Alarm Range: -0.6mV- 0.8mV
l. Arrhythmia Analysis:
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, RONT, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: available
Recall: available

7. RESP
a. Model: RA-LL impedance
b. Measurement/Alarm Range: 0-150 rpm
c. Resolution: 1rpm
d. Accuracy: ±2rpm
e. Suffocation Alarm: 10-40s

8. NIBP
a. Method: Automatic oscillography
b. Working Mode: Auto/Manual/Continuous
c. Interval of Auto Mode: 1-90 min
d. Measurement Time Under Auto Mode: 5 min
e. Measurement and Alarm Range:
Adult: SYS 40-270, DIA 10-215, MEAN 20-235mmHg
Pediatric: SYS 40-200, DIA 10-150, MEAN 20-165mmHg
Neonate: SYS 40-135, DIA 10-100, MEAN 20-110mmHg
f. Alarm Type: SYS, DIA, MEAN
g. Error: ±10% or ±8mmHg, which is higher
h. Overload Protection:
Adult: 315±10mmHg
Pediatric: 265±10mmHg
Neonate: 155±10mmHg

9. SpO2
a. Measurement Range: 0-100%
b. Alarm Range: 0-100%
c. Resolution: 1%
d. Pulse:
Measurement Range: 0-250bpm
Alarm Range: 0-100%
Resolution: 1bpm
Error: ±2bpm

10. Temperature
a. Channel: 2 channels
b. Resolution: 0.1 degrees Celsius
c. Accuracy: ±0.1 degrees Celsius
d. Average Measurement Time: < 10sec
e. Alarm: Audio, video

11. Recorder (optional)
a. Type: Built-in, thermal array recorder
b. Recording Mode: Manual, alarm, and timing
c. Recording Speed: 25/50 (mm/s)
d. Channels: 2
e. Function:
Parameter alarm recording
Waveform freeze recording
Trend list/graph recording
Alarm event review recording
NIBP review recording
Monitor information recording

12. CO2 (optional)
a. Operating Principle: Infrared spectroscopy
b. Measuring Mode: Main stream or side stream
c. Measuring and alarm range: 0% to 13%
d. Accuracy:
< 5.0% CO2 (at ATPS): ± 2 mmHg
> 5.0% CO2 (at ATPS): < 10% of reading
e. Warm-up Time: 2~15 seconds
f. Response Time:
Detector: 28mSec (typical)
System: ~100mSec

13. IBP (optional)
a. Channels: 2
b. Measuring Range:-100~400 mmHg
c. Accuracy: ±2% or ±1mmHg, use the larger value.
d. Resolution: 1 mmHg
e. Alarm Range:
SYS 40~240mmHg
DIA 10~180mmHg
MEAN 20~200mmHg

Remark: Specifications subject to change without prior notice.

Related products
Send Message