DC Self-cleaning Static Elimination Air Blower / ESD Ionizer

DC Self-cleaning Static Elimination Air Blower / ESD Ionizer

Description:
The DC self-cleaning static elimination air blower is easy to install, features stable operation, and performs rapid static elimination.

Parameter
Model STC-801ZL
Operating voltage 110 V or 220V
Current consumption 0.04A or 0.08A
Air volume 50 ~ 90CFM
Operating temperature 0~25°C
Case material Pre-painted cold rolled sheet
Size 190mm (L) x90mm (W) x245mm (H)
Weight 2.2kg
Ion balance ≤ ±10V
Testing conditions Testing voltage: +1000V~+100V -1000V~-100V Testing distance: 300mm Temperature: 22°C±5°C relative humidity: < 60%
Static decay time Positive 1.1S Negative 1.2S

Maintenance
1. Cleaning of the emitter
To clean the emitter, firstly, turn off the power of the air blower, then take off the rear net cover and use a cotton swab or clean cloth dipping with ethyl alcohol to clean the emitting needle. This should be performed at least twice every two weeks.

2. Cleaning of the inlet and outlet of the air
The air inlet net and the ionized air outlet net should be kept clean to prevent blocking the airflow by using soft brush or compressed air.

3. Ion balance testing
Use the electrostatic analyzer to measure the ion balance (residual voltage).

4. Static elimination time testing
Use the electrostatic analyzer to measure the static elimination time.

5. The ion output of this DC self-cleaning ionizer is designed to be stable and fixed
The offset of the ion balance (residual voltage) may occur for being affected by voltage fluctuation, humidity of the ambient air and other factors.

The offset standard: 0V±10V.

Index
static eliminator, air ionizer, air fan, industrial electrostatic control

Related products